Delavan Protek nozzle valve, 100psi
$19.9519.95Delavan Protek 60101-2 nozzle valve for use with 100 psi pumps; opens at 60 psi, closes at 45 psi; replaces 60030-2
More Details
Delavan Protek 60101-2 nozzle valve for use with 100 psi pumps; opens at 60 psi, closes at 45 psi; replaces 60030-2
This part replaces those listed below:
manufacturer | part number(s) | ||||||||
---|---|---|---|---|---|---|---|---|---|
Delavan | Protek 60101-2 | Protek601012 | |||||||
Protek 60030-2 | Protek600302 |
Reviews
Featured positive reviews:
Part worked perfect, fast shipping, installed in 10 minutes and stopped my post shut off after drip in my bekett oil burner right away thanks agin
Delavan is my preferred choice each year. Keep that furnace clean w new nozzles and life is good. Works like a charm.
After further investigation the pro tek valve works exactly as intended. My leak was from a pump seal going bad.
I order and I get what I order, I have no issues and would recommend Keith Specialty for oil burner parts
Parts were as advertised and arrived quickly. Very satisfied with this retailer. Will order again.
Nozzle and check valve worked as advertised.
Great product
Price was right, shipping fast, great web site, is all good.
Nozzle valve works perfectly, and shipping was very fast
Featured negative reviews:
Did absolutely nothing to stop the afterdrip on my Beckett burner which is puzzling as it is supposed to close the oil flow below 45psi.
Our responseThree things will create afterdrip of the nozzle: 1. Air n fuel line, 2. Bad check valve at the pump, and 3. The combustion head getting too hot. If the Protek did not stop the afterdrip, these items then need to be checked.